• Fluorine free Foam fire extinguisher coming soon
Reliable, stored-pressure protection

Designed for immediate deployment, these stored-pressure foam fire extinguishers use a fluorine-free extinguishing agent that combines effective cooling and surface sealing to help control fire and prevent reignition.

Designed for Class A and B fire risk, our stored pressure, fluorine-free foam fire extinguishers provide effective protection against fires involving solid combustible materials and flammable liquids, including solvents, hydrocarbons and paints. Fine water droplets absorb heat to cool the fire, while the foam additive improves wetting and penetration. On flammable liquids, the foam forms a layer over the fuel surface, helping to suppress flammable vapours and reduce the risk of reignition. Manufactured from coated steel for increased durability in demanding marine conditions, the range includes portable 9 litre and mobile 45 litre and 135 litre models. Wall brackets, storage cabinets and other fire extinguisher accessories are also available.

What fluorine-free means

The manufacturer describes the extinguishing agent as fluorine-free and manufactured without the intentional addition of PFAS, PFOS or PFOA. Customers requiring confirmation against a specific regulatory definition, flag-state requirement or procurement policy should refer to the current manufacturer declaration and product documentation.

Storage

Store the extinguisher upright in its designated location, protected from direct sunlight, heat sources, excessive moisture, and physical damage. Keep the extinguisher accessible and ensure that its operating instructions remain visible and legible.

  • Stored-pressure design enables immediate deployment and straightforward operation
  • Fluorine-free foam technology supports the transition away from fluorinated firefighting foams
  • Corrosion-resistant construction enhances durability in demanding marine environments
  • Available in portable and wheeled versions to suit different risk areas and applications
  • MED approved for marine use

SKU Product Name
SKU Product Name

Filename Size Brand Regulation Approval body Download
Pdf Icon {{ approvalCertificate.displayFileName }} {{ approvalCertificate.size }} {{ approvalCertificate.brand }} {{ approvalCertificate.regulation }} {{ approvalCertificate.approvalBody }} Download
View all View less
Pdf Icon
{{ approvalCertificate.displayFileName }}
Size: {{ approvalCertificate.size }}
Brand: {{ approvalCertificate.brand }}
Regulation: {{ approvalCertificate.regulation }}
Approval body: {{ approvalCertificate.approvalBody }}
Download
View all View less

Filename Download
Pdf Icon {{ datasheet.displayFileName }} Download
Filename Download
Pdf Icon {{ donningInstruction.displayFileName }} Download
Filename Download
Pdf Icon {{ msd.displayFileName }} Download
Filename Download
Pdf Icon {{ brochure.displayFileName }} Download
Filename Download
Pdf Icon {{ ecDeclaration.displayFileName }} Download
Filename Download
Pdf Icon {{ manual.displayFileName }} Download
Filename Download
Pdf Icon {{ leaflet.displayFileName }} Download
Filename Download
Pdf Icon {{ technicalDatasheet.displayFileName }} Download
Filename Download
Pdf Icon {{ technicalDrawing.displayFileName }} Download

Regular inspection and maintenance should be carried out in accordance with the manufacturer's instructions, applicable regulations and vessel maintenance schedules to ensure optimal performance and regulatory compliance. Following discharge, the extinguisher must be removed from service and recharged by trained service personnel using approved components and extinguishing media. As stored-pressure fire extinguishers cannot be recharged on board ship, spare extinguishers of the same type and capacity must be carried. The number of spares must be equivalent to 100% of the first ten extinguishers carried on board, plus 50% of the remaining extinguishers, up to a maximum of 60 spare units. Survitec provides inspection, maintenance and recharge services via our global service network. To book our fire extinguisher services, please contact your account manager or your local customer service office.

Fluorine-free Foam Stored Pressure Fire Extinguishers
Variant: 9 l portable 45 l wheeled 135 l wheeled
Fire class: A, B A, B A, B
Fire rating: 27A 183 B A – IV B A – IV B
Capacity: 9 l 45 l 135 l
Working pressure: 15 bar 15 bar 15 bar
Test Pressure: 27 bar 30 bar 30 bar
Maximum pressure (PS max): 16 bar 20 bar 20 bar
Minimum discharge time: 43 seconds 203 seconds 424 seconds
Minimum discharge range: 4.5 m 10 m 10 m
Operating temperature: +5°C to +60°C +5°C to +60°C +5°C to +60°C
Weight (full): 13.9 kg 72 kg 270 kg
Weight (empty): 5 kg 24 kg 135 kg
Hose length: 600 - 800 mm 5 m 5 m
Voltage: Suitable for use near live electrical equipment up to a voltage of 1 kV and a minimum distance of 0.5 m, as specified on the product label. Not suitable for use on live electrical equipment Not suitable for use on live electrical equipment
Approvals: EN3-7+A1, MED, PED, APRAGAZ BENOR, NF AFNOR EN1866-1/2, MED, PED, APRAGAZ EN1866-1/2, MED, PED, APRAGAZ

SKU Product Name
Marine Brackets for Portable Fire Extinguishers View

SKU Product Name
FFCABJB82 JB82 Fire Extinguisher Cabinet View
SKU Product Name
FFCABJB65 JB65 Wheeled Fire Extinguisher Cabinet View

Yes. The manufacturer describes the extinguishing agent as PFAS-free (fluorine-free) and free from PFOS and PFOA. If you require confirmation against a specific PFAS definition, procurement policy, flag state or regional regulation please refer to the manufacturer’s product declaration and approval documentation.

A stored pressure fire extinguisher (also known as a permanent-pressure or constant-pressure fire extinguisher) is continuously pressurised and so does not require a separate pressurisation step during operation; the extinguishing agent is expelled directly from the cylinder when the extinguisher is activated. A cartridge-operated fire extinguisher keeps the firefighting agent in an unpressurised main tank and stores the propellant gas in a separate cartridge until the unit is activated.

Some foam extinguishers can be used near live electrical equipment, but only where this is specifically confirmed by the product’s testing, approval and operating instructions. Where electrical equipment itself is the primary fire risk, a different extinguishing medium may be more appropriate. Always select and use fire extinguishers in accordance with the vessel’s fire-control plan, applicable regulations and the product instructions.

PFAS-containing foam extinguishers require specialist disposal and must not be discharged into drains, the sea or the wider environment. Use an authorised waste-management provider that can identify the foam chemistry and arrange the appropriate treatment or destruction route in accordance with local requirements. Contact Survitec for advice on managing the replacement and disposal of legacy extinguishers.

Contact Us

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.